24 November 2026 · 15 min

Company Spotlight: Neosoma Brain Mets - AI Contouring for Radiosurgery

OncologyRadiology & ImagingFDA Clearances

We dive into the FDA 510(k) summary for Neosoma Brain Mets, an AI tool cleared to automate the segmentation of brain metastases on MRI. We unpack the performance metrics, its substantial equivalence to predicate devices, and what this means for radiation oncology workflows.

Key points

Source: FDA 510(k) summary K252922: Neosoma Brain Mets (Neosoma) - U.S. Food and Drug Administration, 2025

This episode is an AI-generated conversation summarising a public document; the hosts' voices are synthetic. It is for information only and is not medical advice. Always refer to the original source.

Company: Neosoma (neosomainc.com) · Product: Neosoma Brain Mets · FDA 510(k) K252922

Your company here. This podcast is looking for its first sponsors: reach clinicians, health-system leaders and medtech and pharma teams following AI in medicine. Sponsorship options and rates →

Transcript

Maya: Imagine automating the contouring of brain metastases with an AI that achieves a sensitivity of 0.90 and throws a false alarm on average just 0.57 times per scan.

Sam: Today we are bringing you a company spotlight episode. We are diving deep into the FDA 510(k) summary for Neosoma Brain Mets, which was published by the U.S. Food and Drug Administration on December 17, 2025.

Maya: Before we get into the details, a quick reminder that our voices are AI-generated and this is a summary of a public FDA document. This is not company marketing material.

Sam: So Maya, let us set the stage. What exactly is the Neosoma Brain Mets software, and why did the FDA need to clear it?

Maya: According to the document, it is a Class II medical device, categorized under the regulation name 'Medical Image Management And Processing System'. Specifically, it is a Software as a Medical Device, or SaMD, meant for the 'semi-automatic segmentation of previously diagnosed brain metastases'.

Sam: Segmentation. For anyone outside of radiation oncology or radiology, that means drawing the physical boundary around a tumor on a scan. When a patient has brain metastases, they often have multiple tiny tumors scattered throughout the brain. Outlining every single one of those by hand on every slice of an MRI is an incredibly tedious process.

Maya: Exactly. The manual process takes a lot of time. The indications for use state that this software uses 'deep learning neural networks', which is a type of artificial intelligence, to contour these tumors on MRI images. It is built specifically for qualified and trained medical professionals.

Sam: I want to highlight a key phrase you just used: 'previously diagnosed' brain metastases. That tells me this AI is not a screening tool, right?

Maya: That is absolutely correct. The summary explicitly states the software is 'not intended to be used to detect tumors for diagnosis'. It even notes that the standard criterion for diagnosing brain metastasis includes having a known primary cancer that has already metastasized to the brain. Because of this, it is not intended for use with images representing other types of brain lesions.

Sam: So a patient comes in, they already have a known cancer that has spread, and the care team knows they are dealing with brain metastases. They run the MRI through this software. What does the output actually look like in a clinical setting?

Maya: The software takes in a T1 post-contrast sequence. From there, it uses machine learning based on pixel signal intensity to perform the segmentation. The volume of the tumor is then calculated using non-machine-learning post-processing. The final output provides post-processed images with color-coded segmentations and volumetric measurements.

Sam: That sounds incredibly useful for tracking whether a tumor is growing or shrinking. But where does this fit into the actual treatment workflow? Does the AI just push these contours straight to the radiation machine?

Maya: Not quite. The summary is very clear about the limitations. When used in a radiation oncology planning workflow, it generates 'Gross Tumor Volume' contours, often called GTV. However, the technology is strictly for 'informational purposes only'. It is not intended to replace the clinician’s current standard practice of manual contouring.

Sam: So the human expert is still entirely responsible for the final boundaries.

Maya: Right. The document says medical professionals 'must finalize' the contours. They have to confirm or modify them using an external platform available at their facility. That means a hospital needs existing software that supports DICOM viewing and editing, like an image visualization software or a treatment planning system.

Sam: That is a vital detail for hospital IT and procurement teams. You are buying the AI engine, but you still need your existing DICOM viewers and treatment planning systems to actually review and edit the contours. The AI does not alter the original MRI image itself.

Maya: Exactly. Another important limitation is the patient population. The software is specifically designed and indicated for adult patients only. Later in the device description, the summary defines this demographic strictly as 'age 22 and older'.

Sam: Age 22 and older. That is a very specific cutoff. If a clinic treats pediatric or young adult patients with brain metastases, this tool is off-label for them. Let us pivot to how this actually got cleared. This is a 510(k) summary, which means they had to prove it is substantially equivalent to a device that is already on the market.

Maya: Yes, the FDA determined the device is 'substantially equivalent' to legally marketed predicate devices. The primary predicate device they compare it to is called VBrain, manufactured by Vysioneer Inc., which was cleared under 510(k) number K203235.

Sam: How similar is Neosoma Brain Mets to VBrain? What does the comparison table tell us?

Maya: They share the same regulation number, 21 CFR 892.2050. They both use deep learning neural networks to assist trained medical professionals in radiation therapy workflows by providing initial object contours on T1 contrast-enhanced MRI images. They are both for informational purposes only and neither is meant to replace manual contouring.

Sam: Are there any differences in what they are allowed to look at?

Maya: Yes, the indications for use show a difference in scope. VBrain is intended for generating Gross Tumor Volume contours of brain metastases, but also meningiomas and acoustic neuromas. The subject device, Neosoma Brain Mets, is dedicated solely to known or previously diagnosed brain tumors, and specifically evaluated for the segmentation of brain metastasis.

Sam: That makes sense. It is a more focused indication. I also noticed the summary lists a 'reference device' alongside the predicate device. It lists NS-HGlio, which is also manufactured by Neosoma Inc., cleared under K221738. Why include a reference device from their own company?

Maya: The reference device NS-HGlio is intended for high-grade brain glioma, like WHO grade 4 glioblastoma. The reason they include it here is architectural. The summary states that Neosoma Brain Mets leverages the exact same pre and post processing pipeline components as that reference device. Specifically, it lists 'MRI normalization, atlas registration, and skull stripping'.

Sam: That is fascinating from an engineering standpoint. They took the foundational image processing pipeline—normalizing the scan, registering it to a brain atlas, and stripping away the skull from the data—from their existing glioma product, and built a new machine learning model for metastases on top of it.

Maya: It is an efficient way to build medical software. Interestingly, the reference device NS-HGlio is indicated for patients 18 years of age or older, whereas this new tool is strictly for age 22 and older. It shows how specific clinical testing dictates the final clearance.

Sam: Speaking of clinical testing, let us get into the actual performance data. Clinical leaders always want to know what the testing data set looks like before they trust the metrics. How did they validate this?

Maya: The software was evaluated in a retrospective, blinded, multicenter study. The testing dataset was made up of 70 subjects and 70 MRIs, meaning one scan per subject. Crucially, the summary notes this data was acquired from medical sites inside and outside of the US that were not included in the training dataset, which helps ensure device generalizability.

Sam: 70 MRIs is a relatively compact dataset for validation, but keeping it entirely separate from the training data is the gold standard for avoiding bias. What kind of scanners were used? Does it only work on top-tier equipment?

Maya: They tested it across a solid range of equipment. The data were acquired using standard of care MRI protocols on Canon, GE, Siemens, and Toshiba scanners at both 1.5T and 3.0T field strengths.

Sam: That covers the vast majority of hospital fleets. What about the imaging parameters? When you are hunting for tiny metastases, slice thickness is everything.

Maya: The parameters for the axial T1 post-contrast sequence were representative of routine clinical practice. The slice thickness ranged from 0.5 to 5 mm, the pixel spacing ranged from 0.45 to 1.12 mm, and the spacing between slices ranged from 0.5 to 5.5 mm.

Sam: And the patients themselves in this 70-subject study? Were they representative of the actual population that gets brain metastases?

Maya: Yes, the subjects were within the age range of 28 to 84 and covered a diverse group of ethnic backgrounds. The document states that the distribution of primary cancers in the testing dataset was consistent with the known epidemiology of brain metastases.

Sam: So the clinical testing population started at age 28, which comfortably supports their commercial label of age 22 and older. Now, to measure how well the AI drew the contours, they needed a human baseline. Who provided the ground truth?

Maya: The reference standard was established using three US board certified neuroradiologists with expertise in measuring brain metastases. Their consensus or combined input served as the ground truth against which the AI was judged.

Sam: Getting three specialized neuroradiologists to agree on the exact pixel boundary of a tumor is no small feat. Let us look at the quantitative endpoints. Starting with sensitivity, how well did the AI find the lesions?

Maya: They measured the true positive rate of lesion identification. The acceptance criteria was greater than or equal to 0.85. The device achieved a performance result of 0.90, with a 95 percent confidence interval of 0.87 to 0.94.

Sam: A sensitivity of 0.90 is strong. It means it is finding nine out of ten known lesions. But with any AI tool, if you crank up the sensitivity, you risk flooding the doctor with false positives. What was the false positive rate?

Maya: This is where the results are particularly interesting. The acceptance criteria required 5 or fewer false positive lesions per MRI. The actual result was just 0.57 lesions per MRI, with a confidence interval of 0.35 to 0.80.

Sam: That is massive for workflow efficiency. If a doctor has to delete 5 fake contours per scan, the software becomes a burden. At 0.57 per scan, they are dealing with a false alarm roughly every other patient. That saves real time. But finding the tumor is only half the battle. How accurate were the actual shapes it drew?

Maya: To evaluate the shape, they used the Dice Similarity Coefficient, or DSC. This assesses the degree of overlap between the device output and the reference standard. The acceptance criteria was a DSC greater than or equal to 0.70. The software achieved a 0.86, with a confidence interval of 0.83 to 0.89.

Sam: An overlap score of 0.86 is very solid when you are comparing against a panel of human experts, because human experts often disagree slightly on where the edge of a tumor is. But in stereotactic radiosurgery, the margin of error at the very edge is critical. If the AI boundary spikes outward even a little, you risk blasting healthy brain tissue with radiation. Did they measure the worst-case boundary errors?

Maya: They did. They used the 95th percentile Hausdorff Distance, or HD95, for true-positive lesions. This assesses the maximum boundary distance between the device segmentation and the reference standard. The acceptance criteria was 2.94 mm or less. The AI achieved a maximum boundary distance of 1.78 mm, with a confidence interval of 1.02 to 2.54.

Sam: 1.78 millimeters. To put that in perspective for the audience, in precision radiation oncology, a few millimeters can be the difference between preserving a patient's motor function and causing damage. A 95th percentile error of 1.78 millimeters is well within their defined safety threshold.

Maya: Finally, they measured the Mean Surface Distance, or MSD, for true-positive lesions, to assess the average distance between the device and reference standard surfaces. The target was 0.66 mm or less. The device hit 0.36 mm, with a confidence interval of 0.16 to 0.56.

Sam: So it comfortably passed every single performance threshold they set. Did they slice this data to see if the AI favored certain demographics or certain scanner types?

Maya: Yes, a subgroup analysis was conducted. They looked at the data based on site, imaging manufacturer, field strength, patient race and ethnicity, age, gender, primary cancer, and site geography. The document concludes that overall, the data demonstrated that the device performance is consistent across all sub-groups.

Sam: That consistency across sub-groups is exactly the kind of evidence health-system buyers need when evaluating an AI tool for diverse patient populations. But, looking at the broader FDA letter attached to this summary, what standard warnings did the FDA include?

Maya: The FDA includes its standard language for these clearances. They advise that finding the device substantially equivalent does not mean it complies with other requirements of the Act or other Federal statutes. The company still has to comply with registration, listing, labeling, and medical device reporting requirements.

Sam: Right, the general controls provisions. It also mentions they are subject to the Quality System regulation under 21 CFR Part 820, which covers design controls and corrective actions.

Maya: Exactly. The letter also reminds the manufacturer that the device must comply with the Unique Device Identification System rule, meaning it must bear a unique device identifier on its label. And interestingly, the FDA explicitly notes that they do not evaluate information related to contract liability warranties.

Sam: I always love pointing that out. The FDA is evaluating technical equivalence and safety data, not providing a commercial endorsement or evaluating legal warranties. Bringing it all together, Maya, what is the major takeaway for our listeners?

Maya: For clinical leaders and radiation oncologists, Neosoma Brain Mets represents an FDA-cleared solution to automate the notoriously time-consuming process of outlining multiple brain metastases. With a 0.90 sensitivity and a very low false positive rate of 0.57 lesions per scan, it can generate accurate Gross Tumor Volume metrics quickly. However, it requires a human in the loop to finalize every contour, it requires external DICOM viewing software to function, and it is strictly for adult patients age 22 and older who already have a known cancer diagnosis.

Sam: That wraps up our company spotlight on Neosoma Brain Mets. If you want to read the numbers for yourself, you can find a link to the source document in the show notes.

Maya: And as always, this podcast is for informational purposes only and is not medical advice. Thanks for joining us.